Mateusz Kowalczyk
0332b728e6 Move I2C work out of interrupt context to fix display freeze
The tube library calls delay(100) after every display write and the
BME280 library calls delay(100) when re-initializing after a failed
transfer. Inside the TC3 timer ISR the SysTick interrupt is blocked,
so micros() stops advancing past ~1ms and delay() can spin forever
when its start sample lands exactly at the bottom of the micros()
sawtooth. All clocks derive from the same 48MHz source, so the ISR
phase is locked and one specific code path (display update on a
falling temperature reading) hits the fatal window reproducibly.

ISRs now only raise flags; sensor reads, display updates and timer
rescheduling run from loop(), where delay() works normally.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-06-10 01:37:18 +00:00
cryptogopher
c2af98d588 Display also humidity and pressure
Display update triggered by value change, not interval
2026-02-12 00:10:45 +01:00
cryptogopher
6a0a954814 Update countdown 2026-02-07 16:58:15 +01:00
cryptogopher
8594905748 Add temperature hysteresis
Do not refresh display if value not changed
2022-10-09 22:18:59 +02:00
cryptogopher
814a99f733 Remove buzzer state variable 2022-10-09 21:48:16 +02:00
cryptogopher
7fe04d76cb Extract buzzer to separate file 2022-10-09 21:36:40 +02:00
cryptogopher
f8878d3c37 Replace tone() with custom timer 2022-10-09 20:34:25 +02:00
cryptogopher
374a72fb07 Move tube to separate file 2022-10-09 15:29:30 +02:00
cryptogopher
21512bc4f4 Add temperature and break countdown display 2022-10-09 15:09:52 +02:00
cryptogopher
3872ece37b Join ISRs 2022-10-09 14:40:33 +02:00
cryptogopher
b81b52b204 Replace delay() with ISR_Timer 2022-09-12 00:07:37 +02:00
cryptogopher
3f5ce648d5 Add BME280 temperature display on timer ISR 2022-09-09 13:07:56 +02:00
cryptogopher
4a46ee65b9 Initial commit 2022-09-08 22:54:21 +02:00